Product Weight
910 kg

https://www.walkershammers.com.au/images/carrier-weight-1.png

Product Carrier Weight
13 - 21 t

https://www.walkershammers.com.au/images/oil-flow-range-1.png

Oil Flow Range
90 - 120 l/min

The Rammer R16P breaker is a cost-effective solution to your everyday breaking applications. The R16P’s simple impact unit design with the incorporation of a nitrogen piston accumulator and a second pressure dampening membrane type accumulator provides its users with an excellent power-to-weight ratio.

This 910kg breaker features a robust, silenced and vibration suppressed housing making it ideal for use in urban areas.

R16P is compatible with carriers ranging from 13.0 – 21.0 tonnes. The remote rockbreaker monitoring hardware RD3 is optional for Performance Line breakers.

View Product brochure.

Features
  • Twin handed
  • Vibration and sound suppressed
  • Flange mounting
  • Stone claws on housing
  • Idle blow protector
  • Fast-change tool system
  • RAMLUBE II
  • RD3 incl. (optional)
  • Original RAMMER tools
  • Piston type accumulator
  • Excellent power-to-weight ratio
Applications
  • Secondary breaking
  • Primary demolition
  • Secondary demolition
  • Recycling
  • Trenching
  • Landscaping
  • Hire Fleet

Compatible with Chisel Tool, Moil Point Tool, Performance Pyramid Tool, Standard Blunt Tool.

Full Specs

   
Weight 910 kg
Min. working weight, flange mounted *1 1080 kg
Impact rate (frequency) 280-860 bpm
Operating pressure 160-180 bar
Pressure relief setting *2 210 bar
Pressure relief max 230 bar
Oil flow range 90-120 l/min
Back pressure max 10 bar
Input power 36 kW
Tool diameter 110 mm
Pressure line connection (IN) ORFS ISO8434-3 (1 7/16 - 12UN)
Return line connection (OUT) ORFS ISO8434-3 (1 7/16 - 12UN)
Pressure line size, min. inner diameter 19 mm
Return line size, min. inner diameter  19 mm
Grease connection BSP internal 3/8"
Optimum oil temperature 40-60 °C
Allowed oil temperature range -20-80°C
Optimum oil viscosity at operating temperature 30-60 cSt
Allowed viscosity range 20-1000 cSt
Carrier weight range *3 13-21 t
Noise level, measured (2000/14/EC) 117 dB(A)
Noise level, guaranteed (2000/14/EC) 121 dB(A)

Related products